SERVA Electrophoresis › Formamide
 
Online Shop Login


Home › Formamide

Formamide

molecular biology grade
CH3NOMr 45.04CAS [75-12-7]

DNase/RNase not detected. Suitable as a denaturing agent for nucleic acids in gel electrophoresis or hybridization experiments. Formamide decreases the temperature necessary for the reassociation of complementary nucleic acids.

Assay (from N)
Density (d 20 °C/4 °C):
Heavy metals (as Pb):

min. 99.5 %.
1.132 - 1.135 g/ml
max. 0.0001 %



References:
  1. Sambrook, Fritsch, Maniatis (1989) Molecular Cloning, Cold Spring Harbor Laboratory Press (p. 9.47)
  2. Ed. Ausubel et al., (1999), Current Protocols in Molecular Biology, Wiley & Sons, Inc. (New York, NY), p. 2.10.11-2.10.12
DANGER
Hazard Statements H360D
Precautions P201 - P202 - P281
Reaction P308 +P313
Storage P405 - P501

Rep. Cat. 2MAK/TRK: 18 mg/m3EG-Index: 616-052-00-8EINECS: 200-842-0WGK: 1LHS: 29241900
Storage Temperature: +15 °C to +30 °C


Cat.No. Size EUR
39604.01 100 ml inquire*  
39604.02 500 ml inquire*  
*Please log in to see your actual prices.

PDF Downloads 
Specifications
Sicherheitsdatenblatt
null

Friday, May 25, 2012

Shop Login




Product Inquiry
Name

E-Mail

Product

Message



SERVA News

SERVA Promotions V/2012



Please find current promotions here:


Sonderaktionen (D + A)

Promotions (EU)

SERVA Seminartour 2012


 more

Proteomics Training School


 

4th Protein Rainbow Workshop
2-dimensional Gel Electrophoresis Reloaded

Düsseldorf, 3. - 7. 9. 2012

 more

Now available: New Brochure Protein Analysis!


 more

ICPL™ Quadruplex Plus Kit -


Now with improved sequence coverage by protein double digestion!  more

SERVA Catalog 2010/11 -
valid through 2012


 more

SERVA Promotions V/2012

Close window


Please find current promotions here:


Sonderaktionen (D + A)

Promotions (EU)

Promotions_Eichhorn.jpg

SERVA Seminartour 2012

Close window

Seminartour_2012_rechts.jpg

Anmeldung:

 Graz Dienstag, 12.06.2012
 Wien Mittwoch, 13.06.2012
 Innsbruck Donnerstag, 14.06.2012

Poster: Proteomics_Seminartour 2012

Proteomics Training School

Close window

 

4th Protein Rainbow Workshop
2-dimensional Gel Electrophoresis Reloaded

Düsseldorf, 3. - 7. 9. 2012

Rainbow- Workshop: Anmeldung

Now available: New Brochure Protein Analysis!

Close window

Everygel_Brochure_s.jpg

From Sample Preparation to Image:


SERVA Brochure: Everygel for Electrophoresis (pdf)

ICPL™ Quadruplex Plus Kit -

Close window

Now with improved sequence coverage by protein double digestion!

ICPL-Kit.jpg
SERVA ICPL™ Quadruplex Plus Kit 39233

SERVA Catalog 2010/11 -
valid through 2012

Close window

SERVA-Katalog-2010-Titel_s_1.jpg
Get here your personal copy!

SERVA InfoMail - Get the latest information

Close window

When subscribing to »SERVA InfoMail« you will receive information about the latest product release, special promotions, new jobs at SERVA and more. This service is, of course, free of charge.
You may remove your name any time from the list of recipients.

Quick Order

Close window

Using the Quick Order field, you can add a product to your shopping cart with just one click. All you have to do: enter the Cat.No. as shown in our catalog in the format xxxxx.yy and click the Go!-Button.

H360D

Deutsch:

Kann das Kind im Mutterleib schädigen.

English:

May damage the unborn child.

Français:

Peut nuire au foetus.

Italiano:

Può nuocere al feto.

Español:

Puede dañar al feto.

close

P201

Deutsch:

Vor Gebrauch besondere Anweisungen einholen.

English:

Obtain special instructions before use.

Français:

Se procurer les instructions avant utilisation.

Italiano:

Procurarsi istruzioni specifiche prima dell’uso.

Español:

Pedir instrucciones especiales antes del uso.

close

P202

Deutsch:

Vor Gebrauch sämtliche Sicherheitsratschläge lesen und verstehen.

English:

Do not handle until all safety precautions have been read and understood.

Français:

Ne pas manipuler avant d’avoir lu et compris toutes les précautions de sécurité.

Italiano:

Non manipolare prima di avere letto e compreso tutte le avvertenze.

Español:

No manipular la sustancia antes de haber leído y comprendido todas las instrucciones de seguridad.

close

P281

Deutsch:

Vorgeschriebene persönliche Schutzausrüstung verwenden.

English:

Use personal protective equipment as required.

Français:

Utiliser l’équipement de protection individuel requis.

Italiano:

Utilizzare il dispositivo di protezione individuale richiesto.

Español:

Utilizar el equipo de protección individual obligatorio.

close

P308 +P313

Deutsch:

BEI Exposition oder falls betroffen: Ärztlichen Rat einholen/ärztliche Hilfe hinzuziehen.

English:

IF exposed or concerned: Get medical advice/attention.

Français:

EN CAS d’exposition prouvée ou suspectée: consulter un médecin.

Italiano:

IN CASO di esposizione o di possibile esposizione, consultare un medico.

Español:

EN CASO DE exposición manifiesta o presunta: Consultar a un médico.

close

P405

Deutsch:

Unter Verschluss aufbewahren.

English:

Store locked up.

Français:

Garder sous clef.

Italiano:

Conservare sotto chiave.

Español:

Guardar bajo llave.

close